Skip to main content
Skip table of contents

Bekannte Probleme 11.08.330

Citrix

  • To launch multiple desktop sessions with Citrix HDX RTME and Citrix H.264 acceleration plugin, the following registry key must be enabled. 

    More...
    ParameterAktivieren Sie den Workaround für doppelte RTME-Sitzungen und H264-Beschleunigung
    Registryica.workaround-dual-rtme
    Wertenabled / disabled
  • Dieser Workaround ist nicht anwendbar, wenn Enable Secure ICA für die spezifische Zustellgruppe aktiv ist.
  • Adding smartcard readers during running / active sessions does not work. The reader is visible, but cannot be used due to unknown reader status. Only relevant for CWA versions earlier than 2112.
  • Es gibt bekannte Probleme mit GStreamer 1.0 in Kombination mit Citrix. Diese treten bei Multimedia-Umleitung von H.264, MPEG1 und MPEG2 auf. (GStreamer 1.0 wird verwendet, wenn die Browser-Content-Umleitung aktiv ist.)
  • Browser Content Redirection (BCR) funktioniert nicht, wenn DRI3 und hardware-accelerated H.264 Deep Compression Codec aktiviert sind.
  • Aktiviert DRI3 auf einer AMD GPU mit aktivierter Citrix H.264-Beschleunigung könnte zu einem Freeze führen. Selektiver H.264 Modus (API v2) ist nicht von diesem Problem betroffen.
  • Citrix H.264 Beschleunigungs-Plugin funktioniert nicht mit aktiviert Serverrichtlinie Für 3D-Grafik-Workload optimieren in Kombination mit Serverrichtlinie Videocodec-Komprimierung verwenden > Für den gesamten Bildschirm.
  • Currently, H.264 for Citrix sessions cannot be used in parallel with video input acceleration.
  • Beim Starten von Self-Service ist es möglich, dass der Prozess ServiceRecord segfaulted- Self-Service kann danach nicht gestartet werden.
    Eine Cache-Bereinigung mit einem Neustart ist erforderlich. Außerdem sollten die folgenden Parameter auf "true" gesetzt werden.

    Mehr...
    ParameterBereinigung des UI-Caches nach Beendigung des Self-Service
    Registryica.selfservice.cleanupwebui
    Wertfalse / true
    ParameterStore-Cache nach Beendigung von Self-Service bereinigen
    Registryica.selfservice.cleanupstore
    Wertfalse / true
  • Das Abmelden von Self-Service verursacht einen Segfault mit CWAL 2211 , der die Anwendung beendet. Der Neustart von Self-Service funktioniert.
  • Browser Content Redirection (BCR) funktioniert möglicherweise nicht mitChrome Version 105.0.* oder später.
  • White/ green fragments may appear during desktop launch if JPEG graphical codec is used.
    -There may be problems with webcam redirection at Citrix. To fix the problem, GStreamer 1.0 must be enabled - this can be done either via the registry for the session or by enabling the browser content redirection (BCR).

OSC-Installateur

  • OSC kann nicht mit IGEL Deployment Appliance bereitgestellt werden: Version 11.3 oder höher ist erforderlich für die Bereitstellung von IGEL OS 11.06. und folgende.

AVD

  • AVD MS-Teams Optimierung kann den AVD-Client zum Absturz bringen, wenn H264 Software Decoder verwendet wird (fluh264dec). AVD bevorzugt die Hardware-Decoder (fluvadec), aber wenn es keine Hardware-Decoder gibt oder wenn alle Hardware-Decoder bereits in Gebrauch sind, wird der Software-Decoder verwendet, was den AVD-Client zufällig zum Absturz bringen kann. Wenn er bei einem bestimmten MS-Teams-Aufruf abstürzt, kann es sein, dass er recht bald wieder abstürzt, wenn er denselben Aufruf erneut tätigt. Ein Workaround ist es, eingehendes Video in solchen MS-Teams-Anrufen zu deaktivieren, was eine Option im "..."
  • H264-Hardware-Dekodierung für MS-Teams-Optimierung ist derzeit auf Nicht-AMD-Geräte beschränkt, da es Stabilitätsprobleme auf AMD-Geräten gibt.
  • Scanning images within an AVD session (with the usage of FabulaTech Scanner Redirection) might fail and cause a reconnection if the compression level is set to high quality.
    As a workaround, the compression level must be reduced.

VMware Horizont

  • After disconnect of an RDP-based session, the Horizon main window which contains the server or sessions overview, cannot be resized anymore.
  • Copying Text from Horizon Blast sessions is not possible.
  • Die Bildschirmtastatur im Horizon-Appliance-Modus funktioniert nicht korrekt mit der lokalen Anmeldung.
    Es ist notwendig, die lokale Anmeldung auszuschalten und die folgenden beiden Schlüssel über die IGEL-Registry zu aktivieren:
    userinterface.softkeyboard.autoshow
    userinterface.softkeyboard.autohide
  • Zoom VDI Media Plugin Versionenunter 5.8.0 Horizon Client stürzt beim Verbinden mit dem Remote-Desktop ab, wenn gleichzeitig TC Setup läuft.
  • With the usage of the PCoIP protocol, the virtual channel provided by VMware used for serial port and scanner redirection could freeze on logout from the remote session.
    This happens only with enabled scanner or serial port redirection. The freeze does not occur if both redirection methods are enabled or none of them. The Blast Protocol is not affected by this bug.
    The respective settings can be found in the IGEL Registry:
    vmware.view.enable-serial-port-redir
    vmware.view.enable-scanner-redir
  • Tastatur-Eingabequellen-Sprachsynchronisation funktioniert nur bei Verwendung von lokalem Layout und aktivierten Deadkeys.
    Wenn ein Tastaturlayout verwendet wird, bei dem Deadkeys deaktiviert sind (was der Standard unter IGEL OS ist), fällt der Horizon Client auf das en-US Layout zurück.
  • PCoIP sessions may crash in some cases, switching to Blast Protocol is recommended then. H.264/HEVC encoding can be disabled when overall performance is too low.
  • Client drive mapping and USB redirection for storage devices can be enabled at the same time, but this could lead to sporadical problems.
    Horizon Client tracks the drives which are dynamically mounted and adds them to the remote session using client drive mapping, means USB redirection is not used for these devices then.
    However, in case of devices like USB SD card readers, Horizon does not map them as client drives but forcefully uses USB redirection which results in an unclean unmount.
    As a workaround, the IDs of these card readers can be added to IGEL USB access rules and denied.

Parallels-Client

  • Attached storage devices appear as network drives in the remote session.
  • USB-Geräteumleitung wird als experimentell für den Parallels-Client für Linux betrachtet.

Firefox

  • Mit aktivierter Citrix Browser Content Redirection (BCR), Firefox hat keine H.264 und AAC Multimedia Codec Unterstützung. Das bedeutet, wenn Codec-Unterstützung in Firefox benötigt wird, muss BCR deaktiviert werden. Citrix Browser Content Redirection ist standardmäßig deaktiviert.
  • Multimedia playback in Firefox is unstable if GStreamer version 0.10 is active. The default GStreamer version for Firefox sessions.browser\<inst>.gstreamer_version was set to 1.0.

Netzwerk

  • Aufwachen aus dem System-Suspend schlägt auf DELL Latitude 5510 fehl.
  • Wenn Anwendungen so konfiguriert sind, dass sie nach dem Herstellen einer Netzwerkverbindung gestartet werden, und Netzwerk-Mounts konfiguriert sind, können seltsame "Anwendung konnte nicht gestartet werden"-Benachrichtigungen angezeigt werden. Die Anwendungen starten trotzdem.
  • Der Satz von Anmeldeinformationen für den manuellen systemweiten Proxy istgebrochen.

Wi-Fi

  • TP-Link Archer T2UH WiFi-Adapter funktionieren nicht nach System-Suspend/Resume.
    Workaround: Deaktivieren Sie die Systemunterbrechung unter IGEL Setup > System > Power Options > Shutdown.

Cisco JVDI-Klient

  • There may be a segfault shown in the logs (during log out of Citrix Desktop session). Occurs only when using Citrix Workspace app 2010 and Cisco JVDI.

Basis-System

  • Hyper-V (Generation 2) benötigt viel Speicher (RAM). Der Maschine muss eine ausreichende Menge an Speicher zugewiesen werden.
  • Aktualisierung vom Speicherstick erfordert Netzwerk-Online-Zustand (zumindest wenn mehrere Aktualisierungsstufen ausgelöst werden / notwendig sind).

Conky

  • Der rechte Bildschirm bei Verwendung einer Multiscreen-Umgebung wird möglicherweise nicht korrekt angezeigt.
    Abhilfe: Der horizontale Offset sollte auf die Breite des Monitors gesetzt werden (z.B. wenn der Monitor eine Breite von 1920 hat, sollte der Offset auf 1920 gesetzt werden).

Firmware-Aktualisierung

Appliance-Modus

  • When ending a Citrix session in browser appliance mode, the browser is restarted twice instead of once.
  • Appliance-Modus RHEV/Spice: spice-xpi firefox plugin wird nicht mehr unterstützt.
    Der Konsolenaufruf muss Native client zulassen (auto ist auch möglich) und sollte im Vollbildmodus gestartet werden, damit sich keine Fenster öffnen.
  • Browser Appliance Modus kann fehlschlagen, wenn die Web URL spezielle Steuerzeichen wie Ampersands (& Zeichen) enthält.
    Abhilfe: Fügen Sie Anführungszeichen am Anfang und am Ende einer betroffenen URL ein. Beispiel: 'https://www.google.com/search?q=aSearchTerm&source=lnms&tbm=isch'

Audio

  • IGEL UD2 (D220) kann die Lautstärke des Lautsprechers nicht wiederherstellen, wenn das Gerät die Firmware-Version 11.01.110 verwendet hat.
  • Audiobuchsenerkennung auf Advantech POC-W243L funktioniert nicht. Daher geht die Tonausgabe über ein eventuell angeschlossenes Headset und auch die internen Lautsprecher.
  • UD3 M340C: Toneinstellungen zeigen Kopfhörer & Mikrofon, obwohl nicht verbunden.

Multimedia

  • Multimedia-Umleitung mit GStreamer konnte bei Verwendung des Nouveau GPU Treibers fehlschlagen.

Hardware

  • Einige neuere Delock 62599 active DisplayPort to DVI (4k) Adapter funktionieren nur auf INTEL-basierten Geräten.
  • Aufwachen aus dem Suspend über UMS funktioniert nicht auf HP mt645 Geräten. Abhilfe: Deaktivieren Sie System Suspendund verwenden Sie stattdessen Shutdown .
  • System-Suspend wird auf Lenovo L14 Gen 3 Intel-basierten Geräten nicht unterstützt.
  • Wenn Bluetooth über das tray-Symbol / Menü auf dem Lenovo L14 Gen3 (Intel-basiert) deaktiviert wird, ist das Bluetooth tray-Symbol dauerhaft deaktiviert. Kann mit dem Konsolenbefehl rfkill unblock bluetooth

Fernverwaltung

  • AIT-Funktion mit IGEL Starter Lizenz wird nur von UMS Version 6.05.100 oder neuer.

Fabulatech

  • Scanning images within an AVD session (with the usage of FabulaTech Scanner Redirection) might fail and cause a reconnection if the compression level is set to high quality.  
      As a workaround, the compression level must be reduced.




JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.