New Features 10.05.500

Citrix

  • Integrated Citrix Workspace app 18.10.
    • There is now a registry key to enable Citrix Workspace App selfservice web UI mode

      More...

      Parameter

      Enable Citrix Workspace app self-service web UI mode

      Registry

      ica.authman.cwacapableenabled

      Value

      enabled / disabled

    • There is now a registry key to make a Bloomberg v4 keyboard available across multiple sessions. Additionally USB redirection has to enabled at least for this device: vid=1188 pid=9545.

      More...

      Parameter

      Bloomberg v4 keyboard

      Registry

      ica.allregions.bloombergredirection

      Value

      default / true / false

    • Removed parameter for Citrix Cloud. This parameter is not needed anymore.

      More...
      IGEL SetupSessions > Citrix > Citrix Global > Options

      Parameter

      Connect to cloud

      Registry

      ica.cloudconnect

  • Citrix client version 13.9.1 was removed.
    Available Citrix client versions: 13.5.0, 13.10, 18.10 (default)
  • It is now possible to span a citrix session over a self-defined number of consecutive monitors. For this, the parameter ica.wfclient.usexdgfullscreen must be deactivated and ica.pnlogin.spanmonitorenable activated. The selection must be defined in the parameter ica.pnlogin.spanmonitor.

    More...
    IGEL SetupSessions > Citrix > Citrix Global > Window

    Parameter

    Expand the session over a self-selected number of monitors

    Registry

    ica.pnlogin.spanmonitorenable

    Value

    enabled / disabled

    IGEL SetupSessions > Citrix > Citrix Global > Window

    Parameter

    Monitor selection

    Registry

    ica.pnlogin.spanmonitor

    Value

    " "

    Sample: When using four monitors and expansion of session across monitor 2, 3 and 4 is wanted, insertion should be 2,3,4 or 2,4.

  • Setup renaming

    More...
    Old NameNew Name
    Citrix XenDesktop / XenAppCitrix
    Citrix Receiver SelectionCitrix Workspace Client Selection
    Citrix Receiver versionCitrix Client version
    HDX / ICA GlobalCitrix Global
    Legacy ICA SessionsCitrix Legacy ICA Sessions
    Citrix Storefront/WebinterfaceCitrix Storefront
    XenAppCitrix Virtual Apps
    XenDesktopCitrix Virtual Desktops
    XenApp / XenDesktopCitrix Virtual Apps / Desktops
    Server Location: XenApp 6.x or olderServer Location: Web Interface
    Server Location: XenApp/XenDesktop 7.x StoreServer Location: Storefront
    Server Location: XenApp/XenDesktop 7.x Legacy ModeServer Location: StoreFront Legacy Mode
  • Updated deviceTrust client to version 19.1.100.

UDC3 Installer

  • Added UEFI support in UDC Deployment Appliance 5.0, downloadable via download section on www.igel.com

  • Enhanced UDC3 Converter by a new option to force MS-DOS partitioning for EFI installations.

  • Updated "preparestick" tool to version 3.3.0.0 with the following fixes:
    • WMI NullReferenceException
    • dd.exe Processbar asynchronous
      • diskpart->clean failed with access denied
  • RDP/IGEL RDP Client 2

    • Updated deviceTrust client to version 19.1.100.

    VMware Horizon

    • Updated Horizon Client for Linux to version 4.10.0-11053294. Added support for the new features:
      • H.264 High Color Accuracy

        More...
        IGEL SetupSessions > Horizon Client > Horizon Client Global > Server Options

        Parameter

        High Color Accuracy mode

        Registry

        vmware.view.high-color-accuracy-mode

        Valueenabled / disabled
      • Serial port redirection support

        More...
        IGEL SetupSessions > Horizon Client > Horizon Client Global > Serial Port Redirection

        Parameter

        Serial Port Redirection

        Registry

        vmware.view.high-color-accuracy-mode

        Valueenabled / disabled
      • High resolution display scaling and DPI synchronisation

        More...

        Parameter

        Display Scaling

        Registry

        vmware.view.use-display-scaling

        Valueenabled / disabled
      • Relative mouse support

        More...

        Parameter

        Relative Mouse Feature for a Remote Desktop

        Registry

        vmware.view.enable-relative-mouse

        Valueenabled / disabled
      • Automatically hide toolbar

        More...

        Parameter

        Auto-hide menu bar (tool bar)

        Registry

        vmware.view.menu-bar-auto-hide

        Valueenabled / disabled

    Parallels Client

    • Updated Parallels Client to version 16.5.2
      • Fixed: Remote session closes triggered by audio playback

    IBM_5250

    • Enhanced configuration of IBM iAccess Client. The following parameters were added:

      More...

      Parameter

      Open new sessions in a new tab

      Registry

      ibm.iaccess.acssm.opensessionintab

      Valueenabled / disabled

      Parameter

      Always display the tab bar

      Registry

      ibm.iaccess.acssm.alwaysshowtabbar

      Value

      enabled / disabled

      Parameter

      Switch to new tab when created

      Registry

      ibm.iaccess.acssm.switchtonewtab

      Valueenabled / disabled

      Parameter

      Send a warning when closing multiple tabs

      Registry

      ibm.iaccess.acssm.closemultipletabwarning

      Valueenabled / disabled

      Parameter

      Do not start tabbed sessions until the tab is selected

      Registry

      ibm.iaccess.acssm.tabdelayedstart

      Valueenabled / disabled

      Parameter

      New Tab Action

      Registry

      ibm.iaccess.acssm.newtabaction

      Range

      [Disable and Hide] [Run the Same] [Run Other...]

      Parameter

      Tab Placement

      Registry

      ibm.iaccess.acssm.tabplacement

      Range[Top][Bottom] [Left] [Right]

      Parameter

      List of visible menu entries

      Registry

      ibm.sessions.iaccess%.options.deletemenus

      Valuelist of visible menu entries

    Firefox

    • Updated Mozilla Firefox to version 60.3.0ESR 
      Fixes for mfsa2018-27, also known as: CVE-2018-12392, CVE-2018-12393, CVE-2018-12395, CVE-2018-12396, CVE-2018-12397, CVE-2018-12389, CVE-2018-12390.

    Cisco JVDI Client

    • Updated Cisco JVDI client to version 12.1

    Base system

    • Updated French and Dutch user interface translation.

    Driver

    • Philips Speech Drivers for Citrix and RDP version 12.6.36 
      Support of the new Philips dictation devices SpeechOne 6000 and SpeechAir 2000

    Audio

    • Added support for Jabra Xpress mechanism to deploy firmware updates and settings on Jabra USB headsets.

      More...

      Parameter

      File name of Xpress package

      Registry

      jabra.xpress.package_name

      Parameter

      URL hosting Xpress packages

      Registry

      jabra.xpress.package_url

      Parameter

      Login name for access to Xpress package URL

      Registry

      jabra.xpress.package_url_login

      Parameter

      Password for access to Xpress package URL

      Registry

      jabra.xpress.package_url_crypt_password

      Parameter

      Check SSL certificate

      Registry

      jabra.xpress.package_url_ssl_cert_check

      Valueenabled / disabled

      Parameter

      URL of the Audio Device Dashboard server

      Registry

      jabra.xpress.device_dashboard.server_url

    • Added suspend on idle for Jabra wireless headsets. The headsets are set to offline state after 5 seconds of idle time.

      More...

      Parameter

      Suspend on idle

      Registry

      devices.jabra.suspend_on_idle

      Valueenabled / disabled
    • Added parameters to configure the deferred volume synchronization in Pulseaudio.

      More...

      Parameter

      Enable deferred volume

      Registry

      multimedia.pulseaudio.daemon.enable-deferred-volume

      Valueenabled / disabled

      Parameter

      Safety margin

      Registry

      multimedia.pulseaudio.daemon.deferred-volume-safety-margin-usec

      Value8000

      Parameter

      Extra delay

      Registry

      multimedia.pulseaudio.daemon.deferred-volume-extra-delay-usec

      Value0
    • Added a parameter to force configured volumes for in- and output devices in Pulseaudio.

      More...

      Parameter

      Force Volume Settings

      Registry

      userinterface.sound.force

      Valueenabled / disabled

Hardware

  • Added LG CK 500 to supported hardware.
  • Added Dell Wyse 5070 to supported hardware.
    Known issues: 
    • Headset connectors sometimes not recognises a plugged device. 
    • USB3.0 ports on back panel sporaradic not recognises USB3.0 devices correctly.
    • USB-C front displayport usage is not recommended, connection problems could occur. 
    • Wake-up after standby could lead to delay when using multimonitor setup 
    • Screen rotation does not work reliable
  • Added ONYX VENUS 223 to supported hardware.
  • Added support for following Plantronics devices:
    • Blackwire 5210 
    • Voyager Focus UC B825 
    • Voyager 8200 UC

Java

  • Updated Oracle Java Runtime Environment to version 1.8.0 U192.

IGEL Cloud Gateway

  • Added support for ICG High Availability and ICG load balancing to the IGEL remote management service.
JavaScript errors detected