Menu path: Setup > Devices > Printers > TCP/IP > COM 1
-
Activate TCP/IP printers on this port
☑ Maps the interface defined below in a TCP/IP port.
☐ Disabled (default)
-
TCP/IP port number: Port on which the interface is to be mapped (default: 3004).
-
Poll criterion: Criterion according to which the interfaces are mapped.Always: Maps constantly without polling.Online: Maps only if the printer is switched on.
-
Poll frequency: Amount of time between polls (default: 1 sec)
-
Speed: Input and output speed (default: 9600)
-
Parity: Parity bits that are to be used. Possible values:NoneEvenOdd
-
Stop bits: Use up to two stop bits. (default: 1)
-
Word width: Sets the number of bits used per byte.5678
-
Use RTS/CTS flow control
☑ Hardware flow control will be used.
☐ Not used (default)
-
Use XON/XOFF flow control
☑ Software flow control by sending start/stop signs will be used.
☐ Not used (default)
-
Use DSR flow control
☑ Hardware flow control with DSR for output will be used.
☐ Not used (default)