COM 1 / 2

Menu path: Setup > Devices > Printers > TCP/IP > COM 1

  • Activate TCP/IP printers on this port

    ☑ Maps the interface defined below in a TCP/IP port.

    ☐ Disabled (default)

  • TCP/IP port number: Port on which the interface is to be mapped (default: 3004).

  • Poll criterion: Criterion according to which the interfaces are mapped.Always: Maps constantly without polling.Online: Maps only if the printer is switched on.

  • Poll frequency: Amount of time between polls (default: 1 sec)

  • Speed: Input and output speed (default: 9600)

  • Parity: Parity bits that are to be used. Possible values:NoneEvenOdd

  • Stop bits: Use up to two stop bits. (default: 1)

  • Word width: Sets the number of bits used per byte.5678

  • Use RTS/CTS flow control

    ☑ Hardware flow control will be used.

    ☐ Not used (default)

  • Use XON/XOFF flow control

    ☑ Software flow control by sending start/stop signs will be used.

    ☐ Not used (default)

  • Use DSR flow control

    ☑ Hardware flow control with DSR for output will be used.

    ☐ Not used (default)