These instructions are intended solely for recycling organizations for disposal purposes only! After opening the power supply unit, it must no longer be used.


WARNING

  • The disassembly of the device must only be carried out by an electrically qualified person.
  • Touching live parts can cause danger to life and limb from electric shock.
  • Disconnect the device from the power supply before the disassembly.
  • Disconnect all peripherals from the device before the disassembly.
  • Use only insulated tools for the disassembly.

  1. To open the power supply unit, tap the seal on the side of the plastic outer cover with a hammer.



    Once the power supply unit is open, the electrolyte capacitor is accessible.



  2. To remove the PCB from the housing, drive a slotted screwdriver between the PCB and the housing. Pry the PCB out. 




  3. Press down the side cover (1) of the inner shell.

  4. Release two metal legs (2) on the capacitor with pliers.

  5. Remove the capacitor using flat pliers.



Discard the plastic housing, the capacitor, and the board separately and in an environmentally friendly way.