Skip to main content
Skip table of contents

New Features 11.03.100

 Citrix

  • Integrated Citrix Workspace app 19.10
  • Available Citrix Workspace apps in this release: 19.10 (default), 19.08 and 18.10
  • Added a registry key to enable Transparent User Interface [TUI] Virtual Channel [VC] protocol.

    More...
    ParameterEnable VDTUI protocol
    Registryica.module.virtualdriver.vdtui.enable
    Value

    enabled / disabled

  • Updated libwebkit2gtk-4.0-37 to version 2.26.2. It is now possible to enable debug output for Citrix Browser Content Redirection by running the script /config/bin/install-webkit-debug. The debug output is written to /var/log/user/webcontainer.debug.

    Only short sessions with enabled debug output can be tracked, due to the huge amount of debugging data which is written to the log file.

  • Added support for FabulaTech Scanner for Remote Desktop.

    More...
    IGEL SetupSessions > Citrix > Citrix Global > Fabulatech Scanner Redirection 
    ParameterFabulatech Scanner for Remote Desktop
    Registryica.module.virtualdriver.fabulatech_scanner.enable
    Value

    enabled / disabled

RDP/IGEL RDP Client 2

  • Added support for FabulaTech Scanner for Remote Desktop.

    More...
    IGEL SetupSessions > RDP > RDP Global > Fabulatech Scanner Redirection 
    ParameterFabulatech Scanner for Remote Desktop
    Registryrdp.fabulatech_scanner.enable
    Value

    enabled / disabled

VMware Horizon

  • Updated Horizon Client to version 5.2.0-14604769.
  • Added local scanner redirection for VMWare Horizon Client.

    More...
    ParameterScanner Redirection
    Registryvmware.view.enable-scanner-redir
    Value

    enabled / disabled

  • Added support for FabulaTech Scanner for Remote Desktop.

    More...
    IGEL SetupSessions > Horizon Client > Horizon Client Global > Fabulatech Scanner Redirection 
    ParameterFabulatech Scanner for Remote Desktop
    Registryvmware.view.usb.enable-fabulatech-scanner
    Value

    enabled / disabled

ThinLinc

  • Updated ThinLinc Client to version 4.10.1.

Parallels Client

  • Updated Parallels Client to Version 17.0.1 .
    For using the FIPS 140-2 compliance mode no special handling is needed anymore.

Teradici PCoIP Client

  • Updated Teradici PCoIP client to 19.05.9.

Imprivata

  • Added: When available flash is bigger than 2GB, 500 MB will be used for the Imprivata data partition.

Cisco JVDI Client

  • Integrated new Cisco Jabber Softphone for VDI (Cisco JVDI Client) version 12.7 in 64bit.

    More...
    IGEL SetupSessions > Citrix XenDesktop/XenApp > HDX/ICA Global > Unified Communications > Cisco Jabber 
    ParameterCisco JVDI client
    Registryica.module.virtualdriver.vdcisco.enable
    Value

    enabled / disabled

    IGEL SetupSessions > Horizon Client > Horizon Global > Unified Communications > Cisco Jabber
    ParameterCisco JVDI client
    Registryvmware.view.vdcisco.enable
    Value

    enabled / disabled

    > Registry path for Common JVDI options: multimedia.ciscovxme.**

Logging

  • Added Elastic FIlebeat 7.3.0. This is a lightweight way to forward and centralize logs and files. There are new registry keys to enable and configure Elastic FIlebeat

    More...
    IGEL SetupSystem > Firmware Customization > Features
    ParameterElastic Filebeat
    Registryservices.elastic_filebeat.enabled
    Value

    enabled / disabled

    ParameterUse custom configuration
    Registrynetwork.filebeat.custom.enabled
    Value

    enabled / disabled

    ParameterCustom Configuration
    Registrynetwork.filebeat.custom.config
    Value

    filebeat.inputs: ...

Base system

  • Added support for exFAT filesystem.
  • Updated Kernel to version 4.19.85 with WiFi backport drivers 5.3.6.1.
  • Updated Intel microcodes to version 20191115 to fix various security issues (CVE-2019-11135, CVE-2019-0117 and CVE-2019-11139).
  • Updated Xorg Xserver from version 1.19.6 to 1.20.5.
  • Updated Mesa OpenGL stack from version 19.0.8 to 19.2.5.
  • Updated the X11 video and input drivers to their most current available versions.
  • Added functionality to enable or disable touchpad with a hotkey.

    More...
    IGEL SetupUser Interface > Input > Touchpad  
    ParameterEnable Touchpad
    Registryuserinterface.touchpad.general.touchpadenable
    Value

    enabled / disabled

    IGEL SetupUser Interface > Input > Touchpad  
    ParameterHotkey
    Registryuserinterface.touchpad.general.usehotkey
    Value

    enabled / disabled

    IGEL SetupUser Interface > Input > Touchpad  
    ParameterModifiers
    Registryuserinterface.touchpad.general.hotkeymodifier
    IGEL SetupUser Interface > Input > Touchpad  
    ParameterHotkey
    Registryuserinterface.touchpad.general.hotkey
  •  Added feature to log into different files and to store log files on a persistent encrypted partition.

    More...
    IGEL SetupSystem > Logging 
    ParameterLocal logging
    Registrysystem.syslog.enabled
    Value

    enabled / disabled

    IGEL SetupSystem > Logging 
    ParameterUse persistent log partition
    Registrysystem.syslog.persistent
    Value

    enabled / disabled

    IGEL SetupSystem > Logging 
    ParameterPartition size in MB
    Registrysystem.syslog.partsize
    Value

    100


    Create /var/log/auth.log:

    Registrysystem.syslog.sinks.auth
    Value

    enabled / disabled

    Create /var/log/daemon.log:

    Registrysystem.syslog.sinks.daemon
    Value

    enabled / disabled


    Create /var/log/kern.log:

    Registrysystem.syslog.sinks.kern
    Value

    enabled / disabled


    Create /var/log/syslog:

    Registrysystem.syslog.sinks.syslog
    Value

    enabled / disabled

  • Updated Fluendo multimedia codecs to the following versions:

gst-fluendo-h264dec - 18/09/2019 0.10.54

gst-fluendo-vadec - 16/10/2019 0.10.210

  • Added beep sequence to signalize a missing system partition during early boot.

CUPS Printing

  • Updated Printer Installer client to version 25.1.0.303.
  • Added missing cups model names for some printers.

Smartcard

  • Updated MUSCLE Open Source CCID driver to version 1.4.31. Added additional smartcard reader Cherry SECURE BOARD.
  • Updated SecMaker Net iD smartcard library to version 6.8.1.31. The changes are:
    • Support for Gemalto IDPrime 940 and 3940.
    • Support for new VRK card (IDEMIA IAS ECC, spec: FINEID S1 - FINEID S1 Electronic ID Application v4.0).
    • Support for Aventra MyEID v4.0 (customer specific card profile with read support only).
    • Fixed problem with detection of cards in Net iD Card Portal.
    • Other fixes, see release notes at SecMaker.

WiFi

  • Added backports kernel drivers with version 5.3.6-1 for better WiFi support.
  • Disabled backports drivers for Microsoft Surface Laptop 3.
  • Added new registry key to enable or disable the use of the backport drivers (reboot is needed).

    More...
    ParameterUse the newer backport drivers for WiFi
    Registrynetwork.drivers.use_backport_drivers
    Range

    Default (normally use backport drivers) / False / True 

  • Added switch for more aggressively search of configured hidden WiFi networks.

    More...
    ParameterForce connection to hidden network
    Registrynetwork.interfaces.wirelesslan.device0.mssid_force_hidden
    Value

    never / once / continuously

    The default value never preserves the old behaviour.

    Changing can be useful in situations where the system cannot detect any configured WiFi in the environment. If once is selected, the system will blindly try to connect to all configured hidden networks once (until the network as a whole gets started again). In the case of continuously, it will continue trying to connect to hidden networks.

    Remarks: An access point found in this way will be remembered next time and its reconnecting will be faster.  Search for hidden networks in the Wireless Manager is not affected.

Driver

  • Updated Philips Speech Driver to version 12.8.5.
  • Added login with BioSec BS Login Hand Vein Recognition software. The parameters have to be set in IGEL Setup Registry.

    More...
    ParameterLogin with Biosec BS Login
    Registryauth.login.biosec_bslogin
    Value

    enabled / disabled

    ParameterURL of LifePassServer
    Registryauth.biosec.lifepassserverurl
    Value

    localhost:10100

    IGEL SetupSystem > Firmware Customization > Features
    ParameterBiosec BS Login
    Registryservices.biosec_bslogin.enabled
    Value

    enabled / disabled

  • Added Broadcom Tigon3 network driver.

X11 system

  • Added support for secure keyboard input with Cherry SECURE BOARD 1.0
    In secure mode all keyboard input devices are suppressed except pre-personalized Cherry SECURE BOARD 1.0 devices. For the encrypted communication certificates and keys in directories /wfs/cherry/ca-certs and /wfs/cherry/client-certs are required.     

    More...
    IGEL SetupUser Interface > Input > Keyboard
    ParameterSecure keyboard input with Cherry SECURE BOARD
    Registrydevices.cherry_secureboard.enable
    Value

    enabled / disabled

    ParameterDebug messages for Cherry SECURE BOARD
    Registrydevices.cherry_secureboard.debug
    Value

    enabled / disabled

  • Added the possibility to configure the screen brightness with registry keys.

    More...
    ParameterBrightness value
    Registry

    x.xserver0.brightness

    x.xserver0.screen[1-7].brightness

    Range

    0.1 - 1.0 (darker)

    1.0 - 3.0 (brighter)

  • Added new registry keys to be able to configure some modesetting graphics driver options if needed.  

    More...
    ParameterUse DRI3 PageFlip feature
    Registryx.drivers.modesetting.use_page_flip
    Range

    Default (normally use page flip feature) / disabled / enabled

    ParameterUse shadow framebuffer layer
    Registryx.drivers.modesetting.use_shadow_fb
    Range

    Default (normally use shadow framebuffer) / disabled / enabled

    ParameterUse double shadow framebuffer to improve VNC performance
    Registryx.drivers.modesetting.use_double_shadow
    Range

    disabled / enabled

    ParameterUse software cursor for modesetting driver
    Registryx.drivers.modesetting.use_sw_cursor
    Range

    Default (normally disabled)

    ParameterChoose acceleration method
    Registryx.drivers.modesetting.accel_method
    Range

    Default (normally Glamor is used) / Glamor / None

    ParameterForce usage of DRI3 regardless of x.drivers.use_dri3 setting
    Registryx.drivers.modesetting.force_dri3
    Range

    disabled / enabled

Misc

  • Added support for Stratusphere UX from Liquidware.

    More...
    IGEL SetupAccessories > Connector ID Key Software
    ParameterEnable Stratusphere UX CID Key
    Registrystratusphere_ux.cid_key_software.enable
    IGEL SetupAccessories > Connector ID Key Software
    ParameterStratusphere hub
    Registrystratusphere_ux.cid_key_software.hub
    IGEL SetupAccessories > Connector ID Key Software
    ParameterStratusphere machine group
    Registrystratusphere_ux.cid_key_software.machine_group
    IGEL SetupAccessories > Connector ID Key Software
    ParameterStratusphere user group
    Registrystratusphere_ux.cid_key_software.user_group
  • Added the launcher of Login VSI's monitoring tool Login PI to the IGEL OS which can be configured from setup via parameters and started from the UMS.
    Besides of specifying the parameters given below, a SSL certificate must be provided and deployed via the UMS. This has to be obtained from the Login PI server manually. Given the parameters and the certificate, the launcher can be started via job from the UMS.

    More...
    IGEL SetupAccessories > Login PI
    ParameterServer URL
    Registrydebug.tools.login_pi.server_url
    IGEL SetupAccessories > Login PI
    ParameterSecret
    Registrydebug.tools.login_pi.crypt_password

Hardware

  • Added recognition for IGEL UD2 M250C with 8 GB eMMC with product id UD2-LX 51.
  • Added support for IGEL UD3 M350C with product id UD3-LX 60.
  • UD7 with active AMD Secure Processor feature uses new product id UD7-LX 11.
  • Improved support for ADS-Tec VMT9000 devices:
    • Enable rs-232 additional power supply without restart.
    • Enable external wifi antenna without restart.
    • Enable shutdown by ignition off.
    • Enable watchdog service.
  • Added hardware support for LG CL600N.
  • Added hardware support for LG CL600W.
  • Added new registry keys to be able to configure some new i915 parameter

    More...
    ParameterDisable the use of limited color range for DisplayPort 1
    Registryx.drivers.intel.dp1_no_limited_color_range
    Range

    Default / disabled / enabled

    Info: Only for M250C the use of limited color range for DP1 is disabled.
  • Added support for newer Prolific PL2303 USB serial adapters (used in UD3-LX 60).
JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.