IGEL UMS Update
In this chapter, you will find how to update the IGEL Universal Management Suite (UMS) under Windows or Linux. Update instructions for the UMS High Availability (HA) installation can be found under Updating the Installation of an HA Network.
Update Instructions
During a UMS upgrade, e.g. from 6.09 to 6.10 or from 6.x to 12.x, the database schema is changed by the installer. With large production databases, this process can last up to 2 hours. Do not abort the installation during this time.
If you have IGEL Cloud Gateways (ICGs) in use and perform a UMS update from version 12.04 or lower to 12.05 or higher, you must restart all existing ICGs after the update installation is completed. For more on how to restart the ICG, see IGEL Cloud Gateway - Managing an ICG Connection in the IGEL UMS and Controlling the ICG Daemon .
If the version of the UMS Console is older than the version of the UMS Server, you will not be able to establish a connection to the UMS Server (Unable to load tree
error message). In this case, you will need to update the installation of the UMS Console.
Update Preparations
Before the installation, check that your hardware and software fulfill the installation requirements. See also Devices Supported by IGEL Universal Management Suite.
Create a backup of the database before updating a previously installed version of the UMS. Otherwise, you risk losing all database content. See Backups and Creating a Backup of the IGEL UMS.
Installing a version of the UMS which is older than the one currently used is only possible if you have a backup of the database with the corresponding older schema. You can only switch from an older database schema to a newer one, not the other way around. You should therefore create a backup of your existing system before you start the update.
Since the version of the database schema always corresponds to the current major.minor version of the UMS (i.e. 6.10 for all 6.10.x releases, 6.08 for all 6.08.x. releases), the downgrades are only possible within a major.minor version. Example: you can downgrade from 6.10.140 to 6.10.120, but not from 6.10.140 to 6.09.120.
We recommend that you install the new version of the UMS on a test system before installing it on the productive system. Once you have checked the functions of the new version on the test system, you can install the new version on the productive system. This also applies to hotfixes, patches etc. for the server system and database.
WebDAV downloads (e.g. files, firmware updates) are stored in the ums_filetransfer
directory. Custom file transfer directories are not supported.