AD / LDAP integration
-
Fixed: In special cases the UMS Console did not respond when the Test of an AD configuration was done.
Device Connector
-
Fixed: ICG connected devices could not communicate with the UMS after a 30 day connection to the ICG without reconnect.
Workaround: disconnect and connect the ICG
Device Service
-
Fixed: Import of profile sometimes resulted in wrong configuration.
Files
-
Fixed: File upload via UMS Web App did not support different data directory.
IGEL Cloud Gateway (ICG)
-
Fixed: In some cases, the ICG was not reconnected after UMS/ICG restart.
-
Fixed: UMS console was frozen if ICG was disconnected, and several UMS servers were offline.
-
Fixed: Devices were able to re-register via ICG after deletion.
IGEL Management Interface (IMI)
-
Fixed: Creation of template keys and assignment of key values to devices and device directories via IGEL Management Interface (IMI) worked only for the superuser.
UMS Common
-
Fixed: Wake up command was not working properly in some cases.
-
Fixed: Security Logging Data was missing for LDAP/AD Users (Information of user who performed action was missing).
UMS Web App
Login
-
Changed: Tooltips removed from Username and Password fields.
-
Fixed: Remember me function did not save login data.
Apps
-
Changed: Apps can be searched by Display name.
-
Fixed: The app was not imported properly if the app dependency version was empty.
-
Fixed: The first downloaded app did not appear in the apps list.
Configuration
-
Added: Tooltips for Create New Profile button and Set Default Version button.
-
Fixed: The tooltip remained displayed on the "Clear All Filters" icon in Assigned Devices.
-
Fixed: The edit file dialog was broken when opened from File details.
-
Fixed: Items in the file root directory were counted even if the user had no Browse rights.
-
Fixed: Assign file permissions were not handled properly in all cases.
Configuration Dialog
-
Changed: Removed the possibility to set template keys on special parameters with combined parameters set as dependency because it resulted in confusing behavior (e.g. Wi-Fi Domain and Location).
It is still possible to set template keys in Registry for such cases.
Devices
-
Added: Message if there are no assigned objects in Assigned Object tab.
-
Changed: Shadowing works via Tyrus instead of Jetty.
-
Changed: Previous scan settings are now saved.
-
Fixed: The filter icons in the Assign Objects search did not work properly.
-
Fixed: The "All selected" option in the Scan Dialog did not function correctly.
-
Fixed: The number of devices handled was not correct after multiple scans.
Logging
-
Fixed: Filtering for Logtime "Between" did not work correctly.
-
Fixed: File and CIC actions were logged even when logging was not enabled.
Search
-
Changed: The 'go to settings' button has been removed.
-
Changed: The warning about stacking reindexing has been altered.
-
Fixed: Value for broken comma was incorrect.
-
Fixed: Case sensitivity did not work for any field.
-
Fixed: Cost Center filter did not work correctly.
-
Fixed: Content of the dialog when the "show terms" button was clicked was not displayed.
-
Fixed: Wrong data was shown for the filter "within last"+"1"+"min".
-
Fixed: Combo box values were not sorted alphabetically.
-
Fixed: Export of the search result included all elements, not just the search results.
-
Fixed: Filter "Version" did not function correctly.
-
Fixed: Two or more device attributes with multiple selected items returned incorrect values.
-
Fixed: Device attribute of the date type did not work correctly.
-
Fixed: Issue with search permissions when updating to a newer version.
-
Fixed: Permission update in HA environments could cause issues with database transactions.