Automation in IGEL Universal Management Suite (UMS) helps you perform recurring device-management and maintenance tasks consistently. You can schedule commands for devices, automate UMS maintenance, classify devices during registration, and select target devices dynamically.
This article helps you choose the appropriate automation method and create an example automation in the UMS Web App.
Why Use UMS Automation
Automation helps you spend less time managing devices and more time optimizing your environment, through:
-
Reduced administrative workload
-
Consistent configuration across endpoints
-
Faster operational tasks
A process or a recurring task is a strong candidate for automation, if:
-
it is performed regularly (for example, weekly or monthly).
-
it must be applied to multiple devices.
-
it should run outside business hours.
-
it has a high risk of errors if performed manually.
Choose an Automation Method
You can select from several UMS features that automate tasks based on your goal.
|
Goal |
UMS Feature |
Feature Description |
|---|---|---|
|
Send scheduled commands to devices |
Jobs |
Use jobs to send commands to IGEL OS devices at a specified time. You can use commands like reboot, shutdown, wake up. For details, see How to Create and Manage Jobs in the IGEL UMS Web App |
|
Run recurring UMS maintenance operations |
Administrative tasks |
Use administrative tasks to automate recurring operations in the UMS environment. For example, you can back up the embedded database or delete logging data. For configuration instructions, see How to Configure Administrative Tasks in the IGEL UMS Web App. For recommended maintenance tasks and scheduling guidance, see IGEL UMS Maintenance Tasks and Post-Installation Configuration of the IGEL UMS Server. |
|
Place devices in directories duringreboots |
Default directory Rules |
Use default directory rules to place newly registered devices or devices with changed properties in the appropriate directory. Profiles and other objects assigned to that directory can then configure the devices automatically. For configuration instructions, see: |
|
Select target devices dynamically based on defined criteria |
Saved searches |
Use a saved search when directory membership alone does not identify the devices you want to target with the automation. When an automation runs, the UMS evaluates the saved-search criteria and identifies the matching devices. For details, see Using Advanced Searches in Jobs and Administrative Tasks. |
|
Automated and conventional device naming |
Naming Convention under Device Network Settings |
Enable naming convention to automatically rename devices connected to the UMS. For details, see Device Network Settings in the IGEL UMS. |
Before You Begin
Before creating an automation:
-
Confirm that your account has write permission for the automation and target objects.
-
Schedule disruptive commands outside normal working hours.
-
Verify the target devices before activating the automation.
-
Back up relevant UMS data before configuring tasks that delete data.
Commands such as reboot, shutdown, and firmware update can interrupt active users. Test the job on a small group of non-production devices before assigning it to production devices.
Example Automation: Create a Scheduled Reboot Job
The following example creates a weekly reboot job and serves as an example configuration.
Prerequisites
-
Your account has write permission for jobs and the target devices.
-
You have a device directory or saved search for testing.
Create the Job
-
In the UMS Web App, go to Automation > Jobs.
-
Create a job. For details, see How to Create and Manage Jobs in the IGEL UMS Web App.
-
Under Job Type, enter a descriptive name, such as
Weekly test device reboot. -
For Command, select Reboot.
-
Under Execution time, configure the schedule:
-
Select Repeat on weekdays.
-
Select the required day.
-
Set the start time to an approved maintenance window.
-
-
Under Targets, select one of the following options:
-
Devices: Select a device directory.
-
Saved Searches: Select a saved search that returns only the intended test devices.
-
-
Keep result logging enabled so that you can review the execution results.
-
Review the command, schedule, and target selection.
-
Set the job to Active.
-
Click Finish.
The UMS saves the job and runs it according to the configured schedule.
The user who creates a job must still have write permission for its target devices when the job runs.
Verify the Job
After the scheduled execution:
-
Go to Automation > Jobs.
-
Select the
Weekly test device rebootjob. -
Click Execution History.
-
Confirm that the expected devices appear in the execution results.
-
Review the execution status for each device.